Introdução

This guide explains how to repair a Navien NPE-240A tankless water heater when the display shows error code E110. This code indicates an issue with the air intake vent, which may be caused by a blockage or a damaged air intake collar.

This guide demonstrates how to clear any obstructions and replace the air intake collar.

Note: Before you begin, check the display screen for Error Code E110 to ensure this is the right guide for your tankless water heater.

Caution: Turn off the unit’s power and shut off the gas supply. Failing to do so can cause injury or damage.

  1. ZJUXUNcTSfhGA6Ni
    ZJUXUNcTSfhGA6Ni
    HUTxXyAv3E45Qkr3
    C24gubo3t4PZoiCQ
    • To ensure this is the correct guide for you, check the display screen for Error Code E110.

    • Turn off the power to the unit and shut off the gas supply.

    • Forgetting to turn off power to the unit and shut off the gas supply can result in possible damage or injury.

  2. JQKYsJttYKm6dYBd
    • Use an impact driver with a 5/16" nut driver to loosen the #6 machine nut screw from the clamp.

    • Loosen the clamp and disconnect the pipe and vent collars from the water heater to access the air intake filter.

  3. H4M1iudEMRxfjnWP
    H4M1iudEMRxfjnWP
    EcXaHPJyyGpUGg2B
    • Inspect the air intake filter and vent pipes for dirt or obstructions.

    • Clear any debris by hand if necessary.

    • If the E110 code remains after cleaning, prepare to replace the faulty air intake vent collar.

  4. H6qemYAarUKu1C6w
    H6qemYAarUKu1C6w
    sWAS2nqKNCpN4fjZ
    vWoSuloQNuktGBeT
    • Use an impact driver with a Phillips head screwdriver bit to remove the four 1/2" machine screws that connect the damaged air intake vent collar to the water heater.

    • Remove the damaged air intake vent collar.

  5. ypCLEtfsgusV35FA
    ypCLEtfsgusV35FA
    gLZmfr2xKwnMAvJO
    • Install the new air intake vent collar.

    • Secure the new vent collar with the four 1/2" Phillips machine screws using the impact driver with a screwdriver bit.

  6. ve5tvSRLFKPjg2ot
    • Use the impact driver with a 5/16" nut driver to reconnect the pipe and vent collars to the water heater.

  7. eIlDJLomqmAwXiQv
    eIlDJLomqmAwXiQv
    HCOlqBhdToGi4nRB
    wVxPZriuP2QVZwSb
    • Turn on the power to the unit and open the gas supply.

    • Power on the heater to confirm that the E110 error code no longer appears.

Conclusão

To reassemble your device, follow these instructions in reverse order.